Both are low-hydrogen electrodes of type AWS A5.1 E 7018-1 for structural work. The practical difference lies in the power source: Basic Super works on both alternating current and direct current, while Basic is the targeted choice when you know for certain that you will be welding with direct current.
The power source is decisive
In the past, a lot of welding was done with transformers on alternating voltage. That is an inexpensive, low-maintenance way of welding that worked well for many years. Modern companies work with direct current, generated by rectifiers or inverters. This equipment is lighter, more compact and delivers a more stable arc.
Basic Super is formulated to work on both types of current. That broader applicability makes the product somewhat more expensive. If you work exclusively with direct current, Basic is the more targeted choice for that specific purpose. So it is not a question of better or worse, but of matching the equipment in your workshop.
The technical differences
Feature Basic Basic Super AWS classification A5.1 E 7018-1 A5.1 E 7018-1 Type of current Direct current Alternating current and direct current Mechanical properties down to -50 degrees Celsius -40 degrees Celsius Welding positions All, except vertical down All, except vertical down Diameters 2.5 to 6.0 millimetres 2.5 to 5.0 millimetres Arc characteristics Smooth, very little spatter Easy to control What both products have in common
Both are low-hydrogen electrodes. Hydrogen in the weld metal, in combination with stresses in the structure, is the main cause of cold cracking, also known as hydrogen cracking or delayed cracking. By keeping the hydrogen content low, you reduce that risk considerably.
You further reduce the risk of cold cracking by preheating the base material, keeping the weld joint clean and dry and limiting shrinkage stresses. Basic electrodes absorb moisture from the air, so the way you store them affects the result. The guidelines for this can be found under handling, storage and drying.
When to choose one or the other
- Choose Basic Super when several welding machines are in use or when the power source differs per location
- Choose Basic when the workshop runs entirely on direct current
- Choose Basic when the specification calls for values at temperatures below -40 degrees Celsius
- Consider Basic 55 when you mainly weld root passes and value full penetration
Where you will come across both
Basic and Basic Super are used for structural work on thicker plates where requirements are set for toughness and strength. You will find them in steel construction, pressure equipment, the structural side of the petrochemical industry and heavier repairs. They are also widely used for welding pipe joints in the oil and gas chain, where the choice between the two types is usually made locally based on the available equipment.
The exact type of current, polarity and recommended amperage per diameter are stated on the product data sheet.
Not sure which power source you have? We are happy to think along with you.